SERVICE [FACTORY MODE]
- Enter the factory menu (can use the IR) and press the remote key [◄V-] to “0’, press mute remote key, then press 9,7,3,5 remote key.
- Press [►] key to enter the sub-menu and press MENU key to return the main-menu.
ADJUSTMENTS
Adjust the temperature in CMP, VGA, AV.
Make sure the picture mode is set to “Stand”, the “Picture à Black expand” on the user Menu is set to “OFF”. “Other à Flesh Tone & Adaptive Luma Control ” on
the factory Menu is set to “OFF”. After Alignment, the entire item will change to “ON”
ADC ADJUST
- For CMP input, the test signal is 576i/50Hz,100%, 8 steps colour bar. Select the “Balance à RGB Calibrate” on the factory Menu, then press “à ”, ADC adjust is finished after “OK” is displayed
- For VGA input, the test signal is 1024×768/60Hz white/black grid. Select the “Balance à RGB Calibrate” on the factory Menu, then press “à ”, ADC adjust is finished after “OK” is displayed.
VGA ADJUST
- For VGA input, the test signal is 1024×768/60Hz 16 steps gray bar. Set the “Balance à Tone” on factory menu to “Normal”:
- For the third step form the white bar, Adjust the value of White R,White G,White B, until the color temperature is x=280±5, y=290±5 Y > 220nit
- For the second step form the black bar, Adjust the value of GrayR, Gray G, Gray B, until the color temperature is x=280±5, y=290±5 Y < 25nit
- Repeat, until all is ok
- Adjust the value of Black level.
AV ADJUST
- For AV3 input, the test signal is PAL - 8 steps gray bar. Set the “Balance à Tone” on factory menu to “Normal”:
- For the third step form the white bar, Adjust the value of White R, White G, White B, until the color temperature is x=280±5 y=290±5 Y > 220nit
- For the second step form the black bar, Adjust the value of GrayR, Gray G, Gray B, until the color temperature is x=280±5 y=290±5 Y < 25nit R
- Repeat A&B, until all is ok
- Adjust the value of Black level.
CMP ADJUST
- For CMP input, the test signal is 576i/50Hz-16 steps gray bar. Set the “Balance à Tone” on factory menu to “Normal”:
- For the third step form the white bar, Adjust the value of White R, White G, White B, until the color temperature is x=280±5 y=290±5 Y > 220nit
- For the second step form the black bar, Adjust the value of GrayR, Gray G, Gray B, until the color temperature is x=280±5 y=290±5 Y < 25nit
- Repeat until all is ok
- Adjust the value of Black level
ANALOGUE BOARD SOFTWARE UPDATE By Imran Ashraf
Prepare MTKTOOL UPDATE, update board, serial line.
- Connect PC, update board, and J3 on the main board with serial line
- Provide the STB +5V for main board
- Open “MtkTool.exe” in MTK TOOL program, and set the parameter as below picture.
- Press “Browse” for selecting the SW.
- Press “Upgrade” to download the SW. It will be OK when it shows “100%”
- After downloading SW, it will be long time for Initializing EEPROM.
Procedure - 2
Preparative is same with above.
- Set SYSTEM > Factory Key on factory MENU to OFF. Connect the device as below picture.
- Update the SW follow solution- (3), (4), (5), (6)
MAIN POWER SUPPLY SCHEMATIC{Click on Pictures to Zoom In}