SERVICE MODE - HOTEL MODE - TOSHIBA LCD TV/DVD COMBO - 19DV713B











HOTEL MODE

Downloads Schematics 



To set the Hotel Mode,  follow the steps below:


1. In power on mode, set the VOLUME to minimum.


2. Press and hold the VOL [ – ] button on the TV.


3. Simultaneously press and hold the [3] button on the remote control for more than 2 seconds.  The Hotel Mode setting menu will appear.


4. Use the UP/DN button on the remote control to select your desired item, and then press ENTER.


5. Use the LEFT/RIGHT button to set the item to your desired setting.


6. The Hotel Mode has now been set up.



1. In power on mode, set the VOLUME to minimum.


2. Press and hold the VOL [ – ]  button on the side panel.


3. Simultaneously press and hold the 3 button on the remote control for more than 2 seconds.  The Hotel Mode setting menu will appear.


4. Use the UP/DN  button on the remote control to selectReset, and then press ENTER.  The setting items have now been set to their initial value.






CLICK ON THE PICTURES TO MAGNIFY


*1 Even if the item is set to “No Respond”, the key operation of service mode function is effective.


*2 Even if the three items are set to “Off”, the TV starts up in the same settings when you turned off the power last time.


*3


 (i) Press “OK” on the option item “TV to USB” to start copying. Once it is completed, the value will switch back to “Off”.


(ii) Press “OK” on the option item “USB to TV” to start copying. Once it is completed, the value will switch back to “Off” and the TV will reboot automatically.


(iii) “All the settings” means “Hotel Menu settings” and “user menu settings” (Picture/Sound/Channel/Setup), including “ATV/DTV channel list”.


(iv) Hotel Clone cannot be enabled in the following situations:


> Hotel Clone does not include the factory settings of Backup Zone, such as ADC, WB, Panel ID, SN data, etc.


> The default value of the option items of Picture Setting and Picture Preference (with the exception of “Memory”) will remain unchanged even after Hotel Clone.


 > Hotel Clone cannot be enabled between different models.




> Hotel Clone cannot be enabled between different firmware versions. If this happens, a warning message will appear as below, and the value will switch back to “Off” without any clone action.


The maximum value that Fixed Volume can be set is based on that of Maximum Volume. For example, if Maximum Volume is set  to “30,” the volume range that Fixed Volume can be adjusted is from 0 to 30 or Off.




FUNCTION TESTING _ REMOTE CONTROL KEY CODES






Comments

Popular posts from this blog

Firmware TP.SK516S.PC821

  TP.SK516S.PC21 Firmware Download Available  Imran Ashraf Whatsapp Support QR Code  It's looks like you're searching for firmware or software related to the TP.SK516S.PB802 Mother Board Find the Correct Firmware on my this website  1. Check Your TV Brand & Model    - The TP.SK516S.PC821 is Main Board Number      2. Correct Resolution It's FHD or UHD 3. Get From Trusted Website and Trusted Person Like Imran Ashraf 10 Years in this     - If the firmware isn’t available on this website you may need to contected Imran Ashraf he can arrange your requirements       4. Caution with Firmware Flashing      Never download firmware from untrusted sites —it may contain malware or brick your TV.      - Ensure the firmware **exactly matches** your TV model and hardware version. If You Need Further Help: - Contact Whatsapp Support+923139292880 - Specify the issue (e.g., boot loop, no...

TP.SK518D.PB802

TP.SK518D.PB802 4G, 512  1920x1080 and 1366x768 Resolution Available Samsung IR Working  Firmware Available YouTube Channel Link 1920x1080 Buying Link 1366x768 Buying Link  Whatsapp Message or Call  +923139292880 Filename Type Size (View PDF) Samsung_2009_PDP_Plasma_Training_Manual_[TM].pdf PDF 3.7 MB (View PDF) Samsung_305TPLUS_[SM].pdf PDF 3.8 MB (View PDF) Samsung_510N_510T_710N_710T_910N_910T_[SM].pdf PDF 7.9 MB (View PDF) Samsung_Atlantis_DLP_Training_Manual_[TM].pdf PDF 2.6 MB (View PDF) Samsung_BN41-00521B_[SCH].pdf PDF 365 KB (View PDF) Samsung_BN44-000123E_[SCH].pdf PDF 344 KB (View PDF) Samsung_BN44-00025A_[SCH].pdf PDF 169 KB (View PDF) Samsung_BN44-00038A_[SCH].pdf PDF 238 KB (View PDF) Samsung_BN44-00041A_[SCH].pdf PDF 178 KB (View PDF) Samsung_BN44-00044A_[SCH].pdf PDF 251 KB (View PDF) Samsung_BN44-00050A_[SCH].pdf PDF 416 KB (View PDF) Samsung_BN44-00056B_[SCH].pdf PDF 140 KB (View PDF) Samsung_BN44-00066A_[SCH].pdf PDF 470 KB (View PDF) Samsung_BN44-...

Philips Codes

PHILIPS - 32PF 5320/28 (Service Mode, Error Codes & Fault Finding] Cont:- Philips 32PF 5320  Service Mode, Error Codes & Fault Finding [Cont:] NO PICTURE, BLANK SCREEN WITH CORRECT SOUND OUTPUT. Check whether the user menu is visible. If the user menu is OK, activate teletext mode. If teletext is OK, the problem is in the ADC [B18]&[Columbus 3D combfilter [B19], if present [depending on model]. If the user menu is not visible, check the LCD panel back light is ON. If the back light is OFF, the problem is in the power supply board or LCD panel.  Also check pin 12 (Lamp_ON_OFF) of 1J02.  It should be high, during normal operation. Fault finding purposes, it is important know the following:-   In Pixels Plus and Digital Crystal Clear models, which have an ADC [Analogue to Digital Converter] (B18), and Columbus 3D comb filter (B19), the digital input of the scaler is used for digital video path (Hercules output), whereas the analogue RGB output , a...