HOW TO REPLACE FAULTY T'CON BOARD





 








Part-2



     Normally T'Con board can be located fitted with LCD panel,
either horizontally or vertically.  In most sets, it will be shielded
withe a metal case, screwed upon it, which acts as an electrostatic
shield, as well as a heatsink to main processor IC.  Upon unscrewing out
the metal shield, the T'Con board is exposed, secured by screwing it on
to the chassis.


  

See the normal position to a T'Con board:


















     After locating the T'Con board, carefully check it for any
capacitor fault or any on board surace mounted fuse blown up.  Refer the
schematic diagram of the Tv under service for details.  If found any,
replace them and try once more by connecting it.  Be careful when
unplugging the flat cable connections to this board.  Look for any lock,
if any, at the side of each connecting sockets.  If there is such
locks, pull out the strip wires only after releasing them.  See a
typical connection.








     Be very patient, and concentrate only to work you are doing.
 Never handle board or wire with careless.  As you can see, no ICs on it
can be replaced by normal soldering techniques.  The board  has been
manufactured by automatic PPS; [Pick Place and Solder], machines
controlled by computer and robotic hands.   Before unscrew the board out
from chassis, just unplug all the flat cable connections, and reinsert
them as it was.  Check once more by switch ON the set, after all
connection has been done properly.  Keep all the wire dressings same as
before. If you have damaged any strip wires that connected with, not use
it any more.  Buy new ones' of same connection numbers and dimensions.
 These flat cables can be bought from most of the electronic spare part
selling shops.  




     In rare cases, there might be some alignment be done after this
board replacement.  To do it, you have to enter the service mode option
to your set.  If you are not sound in electronics, seek tech support.  Never enter to service mode option, and change data values there, without proper knowledge.  it might make the set irresponsible to any further commands.






Comments

Popular posts from this blog

Firmware TP.SK516S.PC821

  TP.SK516S.PC21 Firmware Download Available  Imran Ashraf Whatsapp Support QR Code  It's looks like you're searching for firmware or software related to the TP.SK516S.PB802 Mother Board Find the Correct Firmware on my this website  1. Check Your TV Brand & Model    - The TP.SK516S.PC821 is Main Board Number      2. Correct Resolution It's FHD or UHD 3. Get From Trusted Website and Trusted Person Like Imran Ashraf 10 Years in this     - If the firmware isn’t available on this website you may need to contected Imran Ashraf he can arrange your requirements       4. Caution with Firmware Flashing      Never download firmware from untrusted sites —it may contain malware or brick your TV.      - Ensure the firmware **exactly matches** your TV model and hardware version. If You Need Further Help: - Contact Whatsapp Support+923139292880 - Specify the issue (e.g., boot loop, no...

Philips Codes

PHILIPS - 32PF 5320/28 (Service Mode, Error Codes & Fault Finding] Cont:- Philips 32PF 5320  Service Mode, Error Codes & Fault Finding [Cont:] NO PICTURE, BLANK SCREEN WITH CORRECT SOUND OUTPUT. Check whether the user menu is visible. If the user menu is OK, activate teletext mode. If teletext is OK, the problem is in the ADC [B18]&[Columbus 3D combfilter [B19], if present [depending on model]. If the user menu is not visible, check the LCD panel back light is ON. If the back light is OFF, the problem is in the power supply board or LCD panel.  Also check pin 12 (Lamp_ON_OFF) of 1J02.  It should be high, during normal operation. Fault finding purposes, it is important know the following:-   In Pixels Plus and Digital Crystal Clear models, which have an ADC [Analogue to Digital Converter] (B18), and Columbus 3D comb filter (B19), the digital input of the scaler is used for digital video path (Hercules output), whereas the analogue RGB output , a...

Philips Com

PHILIPS - 32PF 5320 [LCD PANEL REMOVAL] DISASSEMBLE PROCEDURE DISASSEMBLY Cautiously pull back the upper part of the anti-static copper foils next to left and right speakers. do this in such a way that the foils are no longer attached to the metal ground plate on which the SSB board is mounted. Disconnect cables  form the "L" and "R" speakers. Unplug the LVDS connector  on the LCD panel. Be careful. This is a very fragile connector.  Unplug connections of the side I/O panel, the Top Control Panel, and the LCD panel on the SSB board Unplug 520 & X530 connectors on the power supply board. Instead of X520 also connector 66B on the other end of flat cable can be unplugged.  Lift the metal frame, together with all PCBs from the LCD panel.  Take care not to damage fragile LVDS cable, the 66B connector, and the anti-static copper foils.  Take care of these too, when later re-assembling the TV set, and replacing the copper foil. After removal of the...