google.com, pub-1990720073119592, DIRECT, f08c47fec0942fa0 Philips PTV2 Skip to main content

Philips PTV2

















PHILIPS; PTV800_PTV805_PTV810_PTV811_PTV815_PTV820_PTV825 _ SERVICE ADJUSTMENTS.

                                                                     PART -1


  • All service adjustment to this chassis are hot voltage wise, So ensure the use of properly insulated tools.



TUNER ADJUSTMENT


  • Turn the set ON, and tune to an on-air station.

  • Connect digital voltmeter to [TP-41] on the small signal panel.

  • Adjust (C341) [Zone E-6] to obtain a reading of 2.5VDC on the meter.

  • This adjustment may effect on-screen menu positioning  as well as other graphics generated set.


RF AGC DELAY


  • Single tuner models. [ASG051 & ASG052]. The adjustment
    control [R202] can be located on the small signal panel in zone area J2.





  1. Tune to a weak station.

  2. Set R202 to its fully counterclockwise position.

  3. Slowly advance it to a point slightly beyond the point of minimum noise in picture.






  • Two tuner models. [ASG053 & ASG054]. Control resistor [R256] can
    be located on the small signal panel zone area K5  Use the adjustment
    procedure as described above, to this adjustment too.

  • Do not advance the control any further, as it may result in an
    overloaded picture.  The range of the AGC voltage supplied to pin [9] of
    the Varactor tuner may vary from 4.2VDC without signal, and 1.87VDC
    with signal.



VCO AND AFT ADJUSTMENT.


Single tuner models.


  1. Cut the shield break point around IC200, and the IF circuitry.  Peel
    the top cover of the shield to gain access to internal circuitry.

  2. Short test points 16A&16B of the varactor tuner module.

  3. Short test point [23] to ground.

  4. Connect DC voltmeter to test point [7].

  5. Turn the set ON, and record the voltage reading from test point [7].  Typically 4.5V to 5.0VDC.

  6. Turn OFF the set, and remove both shorts from test points TP16A/B and TP23.

  7. Connect the coincidence line at the collector of [Q207] to +5V DC line on the tuner.

  8.  Apply local broadcast signal, preferably on-air signal, to antenna terminals and turn the set ON.

  9. Select the cable tuning from the menu item, select channel 36 or other high band inactive cable channel.

  10. While still in cable mode, select local VHF broadcast channel.  The
    tuning system will attempt to tune three times and then lock on to the
    FCC assigned frequency.

  11. Adjust AFT coil [L202] to obtain a reading of +7.5VDC at test point [tp2].

  12. Adjust VCO coil [L204] to obtain the same DC voltage that was noted above.

  13. Remove the jumper wire from coincidence line.

  14. Verify the adjustment by changing between by High Band and local VHF
    broadcast channel, and ensure that the local broadcast channels lock in
    quickly.



Two tuner models.



  1. Cut the shield break points around IC201 and IF circuitry.  Peel
    back the top cover of the shield to gain access to the internal
    circuitry.

  2. Short test points [16C&D] of the varactor tuner module .

  3. Short test point [23A], pin 13 of IC201, to ground..

  4. Connect DC voltmeter to test point [7A].

  5. Turn the set ON and record the voltage reading from test point [7A]; typically 4.5 to 5.0VDC.

  6. Turn OFF the set and remove shorts from test points [TP16C,D&23A].

  7. Connect the coincidence line at the collector of Q207, to 5VDC line on the tuner.

  8. Apply local broadcast signal by the antenna terminal, and turn ON the set.

  9. Select the Cable Tuning from menu options,and select channes 36 or some other high band inactive cable channel.

  10. While still in cable mode, select local VHF broadcast channel. The
    tuning system will attempt to tune three times, and then lock on to the
    FCC assigned frequency.

  11. Adjust the AFT coil [L219] to obtain a reading of +6.6VDC, at test point [TP2A].

  12. Adjust the VCO coil [L220] to obtain the same DC voltage reading at
    test point [TP7A] that was noted in step 5 of this adjustment procedure.

  13. Remove the jumper from the coincidence line.

  14. Verify this adjustment by changing between the high-band and local
    VHF broadcast channel and ensure that local broadcast channels locks in
    quickly.



Continued in part-2



Comments

Popular posts from this blog

Firmware TP.SK516S.PC821

  TP.SK516S.PC21 Firmware Download Available  Imran Ashraf Whatsapp Support QR Code  It's looks like you're searching for firmware or software related to the TP.SK516S.PB802 Mother Board Find the Correct Firmware on my this website  1. Check Your TV Brand & Model    - The TP.SK516S.PC821 is Main Board Number      2. Correct Resolution It's FHD or UHD 3. Get From Trusted Website and Trusted Person Like Imran Ashraf 10 Years in this     - If the firmware isn’t available on this website you may need to contected Imran Ashraf he can arrange your requirements       4. Caution with Firmware Flashing      Never download firmware from untrusted sites —it may contain malware or brick your TV.      - Ensure the firmware **exactly matches** your TV model and hardware version. If You Need Further Help: - Contact Whatsapp Support+923139292880 - Specify the issue (e.g., boot loop, no...

Philips Codes

PHILIPS - 32PF 5320/28 (Service Mode, Error Codes & Fault Finding] Cont:- Philips 32PF 5320  Service Mode, Error Codes & Fault Finding [Cont:] NO PICTURE, BLANK SCREEN WITH CORRECT SOUND OUTPUT. Check whether the user menu is visible. If the user menu is OK, activate teletext mode. If teletext is OK, the problem is in the ADC [B18]&[Columbus 3D combfilter [B19], if present [depending on model]. If the user menu is not visible, check the LCD panel back light is ON. If the back light is OFF, the problem is in the power supply board or LCD panel.  Also check pin 12 (Lamp_ON_OFF) of 1J02.  It should be high, during normal operation. Fault finding purposes, it is important know the following:-   In Pixels Plus and Digital Crystal Clear models, which have an ADC [Analogue to Digital Converter] (B18), and Columbus 3D comb filter (B19), the digital input of the scaler is used for digital video path (Hercules output), whereas the analogue RGB output , a...

Philips Com

PHILIPS - 32PF 5320 [LCD PANEL REMOVAL] DISASSEMBLE PROCEDURE DISASSEMBLY Cautiously pull back the upper part of the anti-static copper foils next to left and right speakers. do this in such a way that the foils are no longer attached to the metal ground plate on which the SSB board is mounted. Disconnect cables  form the "L" and "R" speakers. Unplug the LVDS connector  on the LCD panel. Be careful. This is a very fragile connector.  Unplug connections of the side I/O panel, the Top Control Panel, and the LCD panel on the SSB board Unplug 520 & X530 connectors on the power supply board. Instead of X520 also connector 66B on the other end of flat cable can be unplugged.  Lift the metal frame, together with all PCBs from the LCD panel.  Take care not to damage fragile LVDS cable, the 66B connector, and the anti-static copper foils.  Take care of these too, when later re-assembling the TV set, and replacing the copper foil. After removal of the...