PHILIPS - PTV - 800_805_810_811_815_820_825 - ALIGNMENT PROCEEDINGS.

PART-2

+130VDC - B+ ADJUSTMENT

The adjustment control can be located at the large signal panel in
zone area [A-6]; is (R455).  Upon replacement of large signal panel. of
if suspect of possible problems with +130VDC arise, check and adjust.



  • Connect the +ve lead of digital voltmeter to +130VDC [TP-4].

  • Connect the -Ve lead to isolated ground.

  • Adjust [R455], so that the voltmeter reades +130VDC.



HIGH-VOLTAGE ADJUSTMENT


To do this, a High Voltage Probe and digital volt meter is necessary.


INITIAL PTV SETTINGS



  • Turn the TV ON.

  • Confirm that the 130VDC is OK.

  • Select a Non-Aux input for black picture.

  • Turn the TV Off.




  1. Connect the ground lead of voltmeter to chassis Ground.

  2. Connect the High-voltage probe to meter.

  3. Set the digital multimeter to measure DC volts.

  4. Remove one of CRT anode connections from High-Voltage splitter. Make sure that [R943] is turned fully clockwise.

  5. Insert the probe tip into the CRT anode connection of the High-voltage splitter.

  6. Turn the PTV ON.

  7. Adjust [R943], High_Voltage _adjust, on the large signal panel  [zone H2] for 30Kv.

  8. Turn OFF the PTV.

  9. Remove the High-Voltage probe.

  10. Re-install CRT anode connector into the combo block.

  11. Turn the PTV On, and confirm proper operation.



PROGRAMMING FACTORY DEFAULT VALUES




Service Mode Entry and Exit.



  • Using the remote control, enter digits [0-6-2-5-9-6 > Menu].

  • Depressing the Power button on the front panel of the TV, will
    Exit the Service Mode, and save the current modifications, and turn the
    chassis OFF.



There are 81 registers within the system.  Some of the data held in
these registers should not be altered and others which are factory set
and uneque to unit under test.  It is highly recommended that the
current values held in these registers be recorded.  This procedure
could save a significant amount of time, should a mistake occur causing
an undesirable condition to the unit under test.



DESCRIPTION OF SERVICE MODE


This service mode is used for changing service control register
values from their default values to new values.  When entering this
service mode, the tuning system will attempt to receive the current
register values that are stored in the EEPROM.  If the EEPROM has never
been programmed, default data values will be stored.


Depression of the PWR button on the front panel of the TV while in
this mode, or, setting register 00 to "00", shall cause the tuning
system to write the adjusted values to the EEPROM IC before chassis
power is turned OFF.


ADJUSTMENT OF REGISTERS IN SERVICE MODE


When the receiver is operating in the service mode, all normal
on-screen displays are suppressed and replaced by special display.  This
display has two lines of information at the bottom of the screen.  The
first line of text shows the factory part number of the microcomputer.
 The next set of characters denotes the version of the software
currently operating.  The second line starting from left, has currently
tuned channel. Channel 3 is the default when entering the service mode
setup as most signal generators output comes at channel 3.  If no signal
is available on this channel, pressing the channel Up/Dn button will
allow  to select an active channel.


  • The Cursor Left/Right keys are used to select among the channel, register and data held in that register.

  • The Cursor Up/Dn keys allow the data value to selected items to alter.



Comments

Popular posts from this blog

Firmware TP.SK516S.PC821

  TP.SK516S.PC21 Firmware Download Available  Imran Ashraf Whatsapp Support QR Code  It's looks like you're searching for firmware or software related to the TP.SK516S.PB802 Mother Board Find the Correct Firmware on my this website  1. Check Your TV Brand & Model    - The TP.SK516S.PC821 is Main Board Number      2. Correct Resolution It's FHD or UHD 3. Get From Trusted Website and Trusted Person Like Imran Ashraf 10 Years in this     - If the firmware isn’t available on this website you may need to contected Imran Ashraf he can arrange your requirements       4. Caution with Firmware Flashing      Never download firmware from untrusted sites —it may contain malware or brick your TV.      - Ensure the firmware **exactly matches** your TV model and hardware version. If You Need Further Help: - Contact Whatsapp Support+923139292880 - Specify the issue (e.g., boot loop, no...

Philips Codes

PHILIPS - 32PF 5320/28 (Service Mode, Error Codes & Fault Finding] Cont:- Philips 32PF 5320  Service Mode, Error Codes & Fault Finding [Cont:] NO PICTURE, BLANK SCREEN WITH CORRECT SOUND OUTPUT. Check whether the user menu is visible. If the user menu is OK, activate teletext mode. If teletext is OK, the problem is in the ADC [B18]&[Columbus 3D combfilter [B19], if present [depending on model]. If the user menu is not visible, check the LCD panel back light is ON. If the back light is OFF, the problem is in the power supply board or LCD panel.  Also check pin 12 (Lamp_ON_OFF) of 1J02.  It should be high, during normal operation. Fault finding purposes, it is important know the following:-   In Pixels Plus and Digital Crystal Clear models, which have an ADC [Analogue to Digital Converter] (B18), and Columbus 3D comb filter (B19), the digital input of the scaler is used for digital video path (Hercules output), whereas the analogue RGB output , a...

Philips Com

PHILIPS - 32PF 5320 [LCD PANEL REMOVAL] DISASSEMBLE PROCEDURE DISASSEMBLY Cautiously pull back the upper part of the anti-static copper foils next to left and right speakers. do this in such a way that the foils are no longer attached to the metal ground plate on which the SSB board is mounted. Disconnect cables  form the "L" and "R" speakers. Unplug the LVDS connector  on the LCD panel. Be careful. This is a very fragile connector.  Unplug connections of the side I/O panel, the Top Control Panel, and the LCD panel on the SSB board Unplug 520 & X530 connectors on the power supply board. Instead of X520 also connector 66B on the other end of flat cable can be unplugged.  Lift the metal frame, together with all PCBs from the LCD panel.  Take care not to damage fragile LVDS cable, the 66B connector, and the anti-static copper foils.  Take care of these too, when later re-assembling the TV set, and replacing the copper foil. After removal of the...